Application of mobile cooling fan and its difference from chiller

Regarding the mobile cooling fan, the following description will be made for this type of cooling fan, and in specific aspects, it is for the use of the mobile cooling fan, and the difference between it and the ordinary cooling fan, so that everyone can pass These, to familiarize with and understand it, so that you can add some expertise and broaden your knowledge.

1. The use of mobile cooling fan

Mobile cooling fans are characterized by ease of use and low cost. Therefore, its use occasions mainly include:

Use case 1: office, outdoor public command center and open workshops and other public places.

Use occasion 2: in some machine rooms, as well as in the equipment instrument room.

Use occasion 3: residential, kitchen, and building groups.

In general, as long as it is not convenient to install the outdoor unit, it is possible to use a mobile cooling fan.

2. The difference between mobile cooling fan and ordinary cooling fan
The comparison between the mobile cooling fan and the ordinary cooling fan is basically the same in terms of the power and cooling capacity, and the difference is in the air circulation. Ordinary chillers, whose air volume circulation is for indoor air, and mobile chillers, are for indoor and outdoor air circulation, that is, the exchange of indoor and outdoor air. So, at this point, the two types of chillers are different.
 

3. Mobile cooling fan, do you need to close the door and window when using it?
The mobile chiller does not need to close the doors and windows when it is used. Therefore, the answer to this question is no, because this type of chiller is exchanged through indoor and outdoor air. The purpose of the wind, thus, the purification of indoor air. Therefore, this conclusion will be reached.

Cooling fan group housing material description and work instructions

On the website of the chiller, the following will be specifically mentioned for the chiller group, and this is not yet in front, so I hope everyone can take it seriously and have a good study. The effect, thus, is to impress the important product of the chiller as well as to deepen its understanding of the degree of understanding. Cixi air cooler

      1. Air-cooled chiller unit and chiller, is there a difference between the two?

      This problem, in the view of the chiller manufacturer Wuxi Hulin, the answer is that there is a difference, that is, the two are not the same, can not be equated. Because they are different in the medium that realizes heat exchange, as well as the working conditions and system operating parameters.

      In addition, on the condensation side and the application conditions, if the conditions are different, then it is also different, so it can be said that the difference between them is still very much.

      2. For the air cooler unit, what is its outer casing?

      The outer casing of the air cooler unit can be appropriately selected according to the actual situation and actual needs, and the appropriate material can be selected to obtain a good use effect. However, in general, there are galvanized sheets, galvanized sheet spray, stainless steel sheets, aluminum sheets, and hot dip galvanized steel sheets.
  
      3. What kind of specific work does the cooling fan group need to perform after starting up and cooling normally?

    When the air cooler unit is turned on, first of all, it is necessary to listen to whether the sound of the compressor is normal, and check whether the operation of the air cooler is normal. If there is any problem, it should be dealt with in time. As for the normal temperature drop, it is necessary to check some specific parameters, whether it is normal, such as pressure, temperature, etc. In addition, some important parts should be inspected in detail, there must be no omissions. Yuyao air cooler, Cixi air cooler

      All of the above are about the air cooler group, and at the same time, they are also related to the air cooler. Therefore, I hope that everyone can take it seriously and do so, so that they can make their own learning, instead of nothing, and then waste such a good study. Opportunity, and thus, regret can not be made up.

Cooling fan inlet and outlet mode

The air cooler directly transports the outdoor air to the room through natural cooling, and then discharges the indoor hot air to the outside to ensure that the number of exhaust and air inlets in the room is at least equal. When there are many indoor heating equipment or workers It is necessary to open a few more exhaust ports for ventilation and cooling.
The air inlet of the air blower outside the air blower should ensure smooth air. It should not be installed in places with odor or soot discharge. The support frame should be installed at the installation of the outer machine to ensure the weight of the outer machine and the air supply pipe, and the maintenance is guaranteed. The safety of personnel during the external maintenance.
After measuring the installation mode and location of the equipment on site, check whether the external machine can enter the installation site. If it is not possible to enter directly, it is necessary to talk about the external machine for disassembly, and then follow the sequence according to the order after entering the installation. In addition, it is necessary to determine whether the inlet duct enters the room through the wall or enters through the window. In addition, when the wind duct is arranged indoors, the distance between the pipeline and the ground should be 2.5 meters. In addition, the pipeline route ensures that there are no obstacles to ensure smooth installation. Hangers for wind road pipes.

Design points of air duct air duct system

I believe that everyone is familiar with chillers, and there are many types of chillers, such as household, industrial, and animal husbandry. The evaporative cooling fan increases the air freshness of the room by transporting the space through the cool fresh air, then discharging the air of relatively poor quality in the space, and then reaching the falling space temperature. Let me introduce the design points of the air duct supply system of the air cooler.

Put the air supply port in the local area where the actual temperature needs to be cooled. The local planned air volume of the air outlet is the local air volume of the temperature at which it drops. It is based on the air volume and the speed of the air outlet to determine the air outlet standard. It is usually made of aluminum alloy. Other products such as finished products or wood can be selected according to the actual situation. The type of the product can be used in many ways according to the actual situation, but the best is to use a DC type four-sided air blower single layer or double louver; The tuyere conditioning valve adjusts the air volume.

The standard for the air supply duct is usually planned by the method of assuming the flow rate. The planned time is to save money and make the noise and wind resistance smaller, so that the air volume may be larger. Do not bend the duct elbow too much, so you can reduce the resistance. You can use it without the air duct. If you want to use it, you should use it short. The pipeline should be straight. Do not have too many turns and branches. It is possible to reduce some local resistance losses in the system pipeline. The air supply duct and the air conditioner should be connected by soft receiver, and the air supply duct outside the room should be able to keep warm, and it does not matter inside.

If there is a duct at the time of planning, a valve or a wind baffle should be placed on the branch pipe to adjust the air volume so that its air volume and request meet the planned parameters.