Dynamic News

——

Air - cooled air cooler suddenly does not cool how to do?

Air cooler is a kind of freezing equipment, which can provide temperature control, constant current power supply and voltage regulation. The basic principle of the air cooler is to add a certain amount of water to the structural storage tank of the equipment. According to the industrial cold water mechanism, the cold system will cool, and then the centrifugal pump inside the equipment will introduce the low temperature frozen water into the machine that must be refrigerated. The frozen water will bring the heat of the internal structure of the equipment. Achieve the effect of refrigeration for machinery and equipment. According to the different refrigeration methods of industrial chiller, it is mainly divided into air cooled industrial chiller and ice water unit. The following Xiaobian is just to chat with you about the common air cooled air cooler.

In specific use, when our air cooled air cooler suddenly does not refrigerate, what is the reason?
In the operation of air cooled air cooler, the liquid refrigerant in the air conditioning evaporator constantly draws heat from the water and quickly volatilizes. After the compressor is reduced and the throttle valve of the air conditioning expansion valve, it also becomes ultra-low temperature and low voltage refrigerant into the air conditioning evaporator again circulation system.
1) If the air cooled air cooler is used for too long, the refrigerant will evaporate, and then harm the actual effect of refrigeration. Another reason is that the refrigerant leaks, and then not enough to harm refrigeration, therefore, we should check the refrigerant is enough. In the case of exposed refrigerant, find the leakage waterproof plugging, therefore, we must regularly maintain and remove our own laser chiller filter device, if the blockage is serious, it is proposed to replace the new gas-liquid separator.
2) In addition, there is too much water residue of air cooled air cooler, which is attached to the tap water tube cavity, resulting in insufficient water supply, and thus affecting the actual effect of refrigeration. Therefore, for areas with poor water bodies, water treatment technology or regular cleaning and replacement of water pipes are needed to ensure that the chiller can operate normally.
3) The condenser has not been washed for a long time. The condenser is one of the important parts of the water chiller. It is easy to be corroded after a long time, which leads to the reduction of heat transfer effect of the condenser. When the scale is serious, the pipeline will be blocked, so that the actual effect of the heat transfer of the air-cooled air cooler will lose its effect, and then the actual effect of refrigeration will be affected. Therefore, it is proposed that the condenser be cleaned up and down once half a year.
In general, our own air cooler in use, we must do regular cleaning work maintenance, so that the characteristics of the equipment can be more stable, the service life can be longer, the work efficiency can be higher.

What are the advantages of industrial air coolers commonly used

Industrial air cooler is widely used in enterprise workshops as a cooling ventilation mechanical equipment. Now the application field has gradually expanded to vegetable greenhouse cooling and ventilation in some public places. Some large, small and medium-sized models of industrial air cooler at home are suitable for home cooling air circulation in autumn and winter seasons. Let's take a look at the advantages of industrial air coolers in the refrigeration industry.
1. Low power consumption, in the enterprise time, the power consumption of industrial air cooler is only one-fifth of the traditional central air conditioning, greatly saving the maintenance cost of the processing plant;
2, according to the cooling cooling water curtain for heat conduction refrigeration, without air conditioning refrigerant more refrigeration mainstream media, zero pollution in the use of environmental protection;
3. The cooling speed is quite fast, and the cooling effect is obvious. In the relatively wet and cold areas, the expected cooling effect can reach 5-10 degrees Celsius, and in the hot and dry areas in the north, the expected cooling effect can reach 10-18 degrees Celsius.
4. Industrial air cooler not only cools down but also carries out natural ventilation air circulation of indoor air pollution, always keeps the steam body clean and comfortable, does not produce traditional central air conditioning cold, and has no adverse effect on body health.
5. In operation, the vibration intensity is low, the noise is low, the air volume is large, suitable for the cooling of large, small and medium-sized workshops;
6. The control panel of the industrial air cooler is displayed by the LCD screen, which has the effect of timing switching machine.

How to remove the odor of air cooler

If the central air conditioning is not used for a long time, it will suddenly turn on and cause odor, and the task volume of the air cooler is relatively large in summer, and the odor is hard to avoid after a long time. It is mainly caused by excessive dust accumulation in the air duct and filter screen, which should be carried out on time cleaning operation. It is worth mentioning that if dust accumulates on the screen for a long time, it will not only harm the quality of exhaust air, but also affect the efficiency of water air conditioning, and expand the electricity consumption of water air conditioning.
In addition, after the air cooler is cooled, there is often some moisture inside, so after the cold air organ is off, the air cooler without the function of drying and mildew removal is to slow down immediately, so that the moisture inside will always be in the inside, and over a long time, there will be aspergillus flavus and odor generation, which is a factor causing odor.
But this is not a problem, for this situation, if the service life of the air cooler is not long, the operation of each part is normal, we only need to clean the dust collection net, and then according to the air cooler manual cleaning can deal with this problem. In addition to pay attention to the water must be better, to keep clean and clear. Naturally, if it is an old water air conditioner, you can find our company's engineering and technical personnel to carry out cleaning solutions, and if necessary, maintain some aging parts and accessories, so that the air inlet of the air cooler can repair the health and freshness of the past.

The interface between the air duct and the air cooler

In the cold storage, transport machinery and equipment production and manufacturing automation production lines and other places, air cooler is the summer refrigeration celebrity. The serial communication interface between flame retardant fiber air duct and air cooler is described in detail in the original text, which is actually the installation step of air duct.
There are five steps:
1. Initially create the position of the hanging parts according to the construction drawings, and then use the electric hand drill to hook expansion screws or assemble fixed supports in the wall boxes at the end and end of the flame retardant fiber cloth air duct.
2. Connect the steel wire rope with the hook expansion screw of the wall with the spring lock, and straighten the galvanized steel wire. If the length of the galvanized steel wire is higher than 15m, it can help to straighten the galvanized steel wire with the tightener.
3, along the suspension training galvanized steel wire length direction, in the galvanized steel wire every 1.5~2m above the assembly of a vertical hanging wire, to lift the horizontal galvanized steel wire, to prevent the horizontal galvanized steel wire due to the total weight of the flame retardant fiber duct itself and slack. Ensure that the galvanized steel wire is horizontal after the suspension system flame retardant fiber cloth duct.
4. Create the corresponding flame retardant fiber cloth air duct of each air cooler according to the design drawing, and then connect the front section of the corresponding flame retardant fiber cloth air duct with the air vent of each air cooler with a binding belt. Hang the system on galvanized steel wire in turn according to the symbolic number of each section of flame retardant fiber cloth air duct, and pull up the middle of each section of the pull lock. Note that the hook in the flame retardant fiber cloth duct does not need to contradict the vertical pole.
5. After the installation of the flame retardant fiber cloth drain pipe, open the relevant air cooler, run the flame retardant fiber cloth air duct, and check whether the binding belt of the safety outlet of the flame retardant fiber cloth air duct is firm; Whether the hooks in each section of flame retardant fiber cloth air duct are hung to; The pull is not exhaustive; Whether the cover of the lock block the lock; Whether the hook is inconsistent with the ball screw; Whether the surface of the flame retardant fiber cloth air duct is clean and tidy.