What should we pay attention to in the installation plan of Industrial Water Cooled Air conditioning

The selection of industrial water - cooled air conditioning (industrial air cooler) is very important in all designs. What problems should the designer of Yuchen fresh air system pay attention to? Here is a small edition to give you a detailed explanation:
1. To select the model from the distance between the exhaust air, we first need to understand our own brand. For each type and specification, the exhaust air volume, air pressure, and power consumption and other major parameters need to be understood. Conclusion After installation, the desired effect and temperature reduction effect can not be achieved.
2. Choose the model from the surrounding environment of the wall. As we all know, the air outlet of industrial water-cooled air conditioning is divided into three kinds: upper air outlet, side air outlet and lower air outlet. If the investigation is not careful, sometimes the wall is not enough to install the bottom of the air, but sometimes my business staff, because of the site is not careful, lack of experience and other factors, can not correct the direction of the air outlet, resulting in the construction of the entrance project also need to temporarily disassemble and replace the model, to the customer and company confusion, unnecessary trouble.
3, from the wall bearing capacity to select the model, the first must be clear to install the main part of the wall is a solid wall, or other single wall or steel frame structure, can bear the weight of their customized model, if not related to the actual site situation, it is just to abandon the essentials, and has no essential practical significance, customers will not accept our own plans, It can even be said that after installation, it will lead to more damage to customers, because some industrial water-cooled air conditioners are centrifugal dehydrators, which are particularly heavy. If they fall down after installation, the result will be unsssible design scheme and also a safety risk.
4. Model selection is based on the use experience of the installation site. Here I will take a case as an example. In order to pursue rights and interests and perfect the sales volume of industrial water-cooled air conditioners, some companies blindly expect customers to install more sets of industrial water-cooled air conditioners. Even higher, this kind of not only enhances the installation cost for the customer, but also adds very great pressure to the middle and late use cost, which is a kind of consumption.

How to maintain the air cooler correctly?

When the air cooler is in normal operation, it is usually used with drinking water. For a long time, it is easy to appear that the key parts of the wet curtain and the water in the chamber have a lot of dirt in drinking water, water residual and the machine itself damaged residue. In order to ensure the actual effect of ventilation and cooling of the air cooler, the following aspects about the correct maintenance of the industrial water cooler can be referred to by everyone.

1. When the air cooler stops using, clean the frost layer and ice block in the finned tube radiator with clean cold water, discharge the water in the inflow tray, and then change the axial flow fan to dry the water;

2. When cleaning the cold air machine, first pull out the power cord plug, loosen the screw, take out the back cover, and then wipe the filter screen and wet curtain neatly with a wet rag. Pay attention to not wetting other components when wiping, so as to prevent corrosion of components;

3. The fan of the air cooler should be placed horizontally, and the area placed should be far away from fire or flammable materials to prevent the machine from being burned down without cause;

4. When the air cooler is used, check whether there is dust and other obstacles in the inlet vent. If there is any obstacle, wipe it with a dry rag and use it again.

5. The cold air machine should be cleaned frequently to avoid the blockage of the antipollution filter net or volatile hole. If the air cooler is used for a long time but is cleaned regularly, it will also lead to the continuous deposition of the machine basin dirt, leading to common faults of the machine, which will seriously affect the application and reduce its service life

What are the advantages of industrial production of environmental protection air conditioning and ai

1, indoor air quality is good: environmental protection air conditioning set natural ventilation, ventilation, purification treatment, flavor, cooling in one, improve the gas oxygen star, improve efficiency. Full fresh air positive pressure operation, filter the dust in the air less than 80%μm, remove harmful substances, effectively prevent "air conditioning cold". Air cooler, Ningbo Air cooler

2, adjust the humidity: for the need to increase the humidity of the workplace humidity adjustment.

3, low investment, high efficiency: in the same total area of the installation of central air conditioning and environmental air conditioning, environmental air conditioning is 1/5 of the total investment in household central air conditioning projects.

4. Wide application coverage: It is generally suitable for crowded places, hot equipment and continuous high temperature pyrogen production sites, large places with environmental pollution gas, rich odor or soot and high air quality star requirements. 5, less electricity consumption, electricity consumption per hour is only once: in the same total area of the installation of central air conditioning and environmental protection air conditioning, electricity consumption is only about 1/8 of the traditional central air conditioning.

6, assembly and maintenance is convenient and quick: environmental protection air conditioning can be assembled along the wall building facade, assembly is beautiful and generous, does not occupy the interior space design, do not need professional and technical personnel maintenance, save maintenance costs.

7, the actual cooling effect is super strong: in the southern region, the general cooling can reach the actual effect of 4~10C, in the hot and dry areas can reach 4~15℃, and the cooling is fast.

How to time delay the use of air cooler

1. Clean the air cooler. Open the drainage valve, flushing with tap water can; If the dust or dirt accumulates more, it is necessary to take it out and replace it with tap water.
2. Clean the evaporative filter screen, that is, the wet curtain. Unload the wet curtain, washed with tap water can, if the wet curtain dead washed material, first to use tap water to infiltrate him, directly to the wet curtain spray household central air conditioning cleaning liquid, cleaning liquid to fully permeate the wet curtain for 5min, wash with tap water, until the wet curtain sediment solution can be solved.
3. Daily maintenance of wet curtain air cooler is not used for a long time. The key closed air cooler water stop valve, remove the wet curtain, drain the water in the cold tank together, and thoroughly clean the water pit of the air cooler. After cleaning, install the wet curtain back, turn on the air cooler, exhaust system for 5min~8min, after drying of the wet curtain, the main switch power circuit of the closed air cooler can be used.
4. Odor removal. After the use of wet curtain air cooler for a period of time, if there is no cleaning and maintenance of the air cooler, it may cause the cold air sent by the air cooler to have peculiar smell. At this time, it must be cleaned according to the whole process of the second point above. If there is still a peculiar smell, you can add some chlorinated disinfectant to the water pit of the air cooler under the condition of operation, so that the disinfectant can permeate into every corner of the wet curtain and the air cooler, and reciprocate sterilization and disinfection for several times, you can trend the peculiar smell of the air cooler.