Dynamic News

——

How does environmental protection air conditioning affect air humidity?

Sorching summer comes, in order to ensure the comfort of people a lot of people will choose to install air conditioning, with environmental protection boom lift, environmental protection air conditioning would be one of the hottest product, as is known to all air conditioning open for a long time the moisture in the air will evaporate, air humidity, environmental protection air conditioning can effect on the air humidity is how? Follow the steps of xiaobian to explore it!

We use environmental protection air conditioning is also has a lot of kinds, different products of different brands can effect is not the same, although the main function is common but we are still want to purchase a product affordable, after all, buy a product or performance and price ratio of the main cast products brand, product brand achievement, but choosing the right product is user are responsible for their own a.

When purchasing environmental protection air conditioning cooling equipment, users will consider whether the humidity in the air cooled by water will have an impact on the room. The general indoor humidity is 70-80%, the comfortable humidity of people is 40-65%, and the relative humidity is 40-65% according to the interior design standard. In hot summer weather, the humidity of the air blown out of the environmental air conditioning is almost blown out of the weather is evaporated, so this is not a problem.

Compared with ordinary air conditioning, environmental protection air conditioning is both environmental protection and energy saving can be said to be the first choice for cost performance. If you want to buy environmental protection air conditioning but do not know how to choose, welcome to call for consultation!

A large number of negative oxygen ions can be produced during the operation of the air cooler

Electrons collide with molecules in the air (mainly oxygen) to produce ions, which are negatively charged and are called anions. Anions are everywhere in nature, thunder and lightning, plant photosynthesis; Natural phenomena such as waterfall impacts can produce large amounts of negative ions, which is why people feel the air is particularly fresh during a thunderstorm, in a forest or near a waterfall.
The production principle of anion is mainly as follows:
1. The atmosphere is ionized by ultraviolet rays, cosmic rays, radioactive substances, thunderstorms, storms, soil and air radiation and other factors. The released electrons are absorbed by the Earth and released again, and soon combine with neutral molecules in the air to form negative ions, or anions. The natural anion (that is, the anion that plays a good role and reducing role in the body) has great antioxidant effect and reducing power.
2. Under the action of gravity, water flows at a high speed in natural processes such as waterfall impact, small waves pushing and heavy rain falling, and water molecules split to produce negative ions. Molecular transformation process of matter.
3. Forest trees, leaf tip discharge and green plant photosynthesis formed by the photoelectric effect, ionization of the air produced by negative ions.
4. Some crustal rocks can release certain negative ions.
5. Air anions are generated by artificial anion generation technology, which simulates the natural lightning and high-pressure ionized air to produce negative electrons, which are transmitted by oxygen and carbon dioxide in the air as carriers.

Precautions for the use of industrial air cooler

    Now, industrial air cooler has been widely used in all kinds of work, but when the use of time arrives, there will be all kinds of small problems, in fact, we pay attention to and regularly clean up when we use, can be avoided. Here are the precautions for the use of industrial air cooler!
    Matters needing attention
    Industrial air cooler due to the application of the environment is more complex (mostly for the plant), so it is necessary to maintain, to prevent the occurrence of some accidents caused by fan quality damage, affect the operation. Maintenance of many small points, summarized as follows:
    1. a single wet curtain machine is suitable for cooling 70-100 square meters of room. If you exceed this value, the effect may not be as good, and it is easy to overwork the machine and cause problems.
    2. Before using the air cooler, check whether there are scraps of paper and dust and other sundries in the wet curtain and pool. It should be cleaned 1-2 times during the annual use period, and the water in the pool should be tap water or other clean water.
    3. The fan is the heart of the cooling fan. If there is a failure, the power should be cut off immediately and an electrician should repair it in time. Attention should be paid to the installation of grounding, the removal of impeller should be careful, so as not to make the blade deformation and box collision.
    4. If the air cooler float ball valve control fails and water shortage or overflow drip is found in the pool, it should be adjusted or replaced in time.
    5. if the wet curtain water supply is insufficient or uneven, it is necessary to check whether the water tank is short of water, whether the pump is running and whether the water supply pipeline and water pump inlet is the small hole in the spray pipe is blocked, and check whether the spray pipe is located in the middle of the wet curtain. The normal spray height can not be ignored, if the water level is too low, it is easy to burn out the machine.
    6. the air cooler in the maintenance, to turn off the power, is to cut off the power after a period of time, because long time use will produce static electricity, static electricity will not disappear after the power, so safety after maintenance.
The above is the related content of the precautions for the use of industrial air cooler, I hope to help you.