Why does cold air function save energy and protect the environment?

one When the traditional compressor air conditioning is running, the doors and Windows need to be closed to keep the indoor temperature unchanged. Because the doors and Windows are closed, the fresh air entering the room is less, the indoor ventilation times are low, and the air quality is poor, which makes people produce dizziness, headache and physical discomfort. The indoor temperature of the workshop of the enterprise is high in summer, and the air quality is poor, especially in the workshop that produces harmful gases. If the closed cooling and ventilation is carried out, it will even cause poisoning, causing adverse effects on the human body and the enterprise. The core component of evaporative air conditioner is evaporative wet curtain, which is characterized by good water absorption and ventilation performance, strong texture, water immersion resistance without deformation, corrosion resistance. Through the design of special corrugated Angle can make the water flow directly to the air inlet side, when the fresh air through it, can ensure full contact between water and air. This can not only improve the evaporation efficiency, reduce the temperature, but also effectively filter out harmful substances and dust in the air. Doors and Windows should be opened when evaporative air conditioners are in operation (doors and Windows should not be opened when there is an exhaust system.) , do not have to self-circulation indoor old air, but always provide sufficient fresh natural cold air, high fresh air coefficient, good air quality, do not cause damage to the human body, conducive to normal conduct.
two Workshop cooling fan energy conservation and environmental protection in the aspect of environmental protection: the central air conditioning of the environmental impact is bigger, the chloride ions such as freon has damage to the ozone layer of the atmosphere, in the operation of the condenser is also constantly to heat dissipation, and the evaporative air conditioner unit is no compressor, refrigerant, non-polluting environmentally friendly products, and itself is not around to heat dissipation. In terms of energy saving: in the same process conditions and air conditioning area, central air conditioning energy consumption, and waste; The installation of evaporative air conditioner unit can effectively save energy, the power consumption of evaporative air conditioner unit is only about 15 ~ 50% of the central air conditioning, so that not only can reduce energy consumption for enterprises, but also can really save operating costs, but also can save electric energy, reduce the impact of electricity shortage and work.
3. Less investment, in the same process conditions and air conditioning area, the installation of traditional compressor central air conditioning investment; The total investment of evaporative air conditioning unit is 30 ~ 70% less than that of traditional compressor central air conditioning unit. Under the same technological conditions and air conditioning area, the installation time of evaporative cooling air conditioning project is more than 50% less than that of traditional compressor central air conditioning.
Four. Humidity regulation in some dry indoor humidity regulation, or some need to humidify places, the traditional compressor air conditioning needs the corresponding humidity regulation facilities; The evaporative air conditioner unit can not need humidity regulation facilities, the unit can adjust the air humidity, to meet the needs of the process.
Five. Small occupation area, simple and convenient installation in the same process conditions and air conditioning area, the installation of traditional compressor central air conditioning requires a special room, covers an area of large; The evaporative air conditioner unit is mainly installed on the roof, wall support or indoor machine room, covers an area of less, than the installation of traditional central air conditioning covers an area of about 90% less, some evaporative air conditioner unit does not take up any building space. The central air conditioning system consists of water chiller, cooling tower, cooling water pump, terminal device and other equipment, which is more troublesome to install, while the evaporative air conditioner unit does not need water chiller, cooling tower, cooling water pump, terminal device and other equipment, so the system installation is simple and quick.
Six. Stable performance, reliable quality, easy maintenance the traditional compressor central air conditioning structure is more complex, requires personnel operation and maintenance, and maintenance costs are large; Evaporative air conditioner unit is equipped with automatic electronic control and automatic cleaning function, stable equipment performance, low noise, high efficiency, reliable product quality, convenient operation and management, no personnel operation, simple and convenient maintenance and low cost.

What is the actual effect of cold air mechanism?

Please check the motor condition when repairing the air cooler. Do not use safety wires or other wires with incorrect capacity. In order to ensure the cooling effect, the air is more cloudy areas can be considered to install filters.
If the motor is not running through the inspection of professional machine repair inspectors, the motor may be burned. It is found that the motor runs normally and the water pump does not feed the water pump may be broken. If the drainage valve is not checked, if the blade is reversed, it is not cool to reverse the connection. And so on the maintenance of the fault only through experienced maintenance personnel to understand, where the bad parts can be replaced!
For places with strict requirements on humidity and temperature, consult professional personnel for guidance. If there is any abnormal condition during the operation of the product, please inform the professional air cooler maintenance company or distribution maintenance point for repair.
What is the actual effect of cold air mechanism?
Industrial air cooler is no compressor, no cold coal, pollution-free environmental protection products, it is the use of outdoor full fresh air evaporation cooling principle of cooling and indoor convection ventilation to achieve the purpose of indoor ventilation and cooling. Compared with the traditional compressor air conditioning system, the cost is less than half, and the equipment does not take up any building area. The system is simple, easy to install and maintain, without professional maintenance personnel. Embodies the characteristics of energy saving, humanity, beauty, environmental protection, for electronics, textile, shoemaking, plastic, machinery workshop, cigarette factory, modern family, office, supermarket, hospital, entertainment, waiting room and other environments to provide a perfect solution for ventilation and cooling.
Industrial air cooler which good, cold air mechanism cold actual effect?
Relatively speaking, the air cooler can not be compared with the working ability of a large number of refrigeration of central air conditioning, but the price is lower, relative to the price of 10% to 20% of the central air conditioning, electricity consumption is only 2% of the central air conditioning, so it still attracts many customers. In different areas of our country, the actual effect of the application of cooling fan is not the same, but the actual effect of cooling fan is stronger, in 3 ~ 8℃. The hotter the temperature is, the more significant the actual cooling effect is, and the higher the wind speed is, the better the actual cooling effect is. In addition to cooling, cooling fans can also have the actual effect of worrying about fresh gas and humidification, especially suitable for the physical and mental health of contemporary people and love the requirements of natural ventilation.

How to prolong the service life of the air cooler

1. Clean the air cooler sink. Open the drainage valve and wash it with tap water. If dust or debris precipitation is more, it can be taken out first, and then washed with tap water.
2. Clean evaporation filter, namely wet curtain. Remove the wet curtain and wash it with tap water. If there are substances that are difficult to wash on the wet curtain, it can be permeated with tap water first, and then spray the air conditioning cleaning liquid on the wet curtain. After the cleaning liquid penetrates the wet curtain completely for 5 minutes, then wash it with tap water until the impurities on the wet curtain are removed.
3. Maintenance of wet curtain cooling fan when it is not used for a long time. First close the air cooler water valve, remove the wet curtain, drain the water in the water tank together, and thoroughly clean the air cooler water tank. After cleaning, install the wet curtain, open the air cooler and supply air for 5 to 8 minutes. After the wet curtain is blown dry, close the main power supply of the air cooler.
4. Odor removal. After the wet curtain cold fan is used for a period of time, if the cold fan is not cleaned and maintained, the cold air sent by the cold fan may have peculiar smell. At this moment, just clean the cold curtain and the sink of the cold fan according to the process of the second point above. If there is still a peculiar smell, you can add some chlorine-containing disinfectant to the air cooler sink when the machine is turned on, so that the disinfectant can fully penetrate the wet curtain and all corners of the air cooler, so that the air cooler can be disinfected several times.
Maintenance Precautions
1. When cleaning the wet curtain air cooler, completely disconnect the main power supply of the air cooler, and hang the "Maintenance, do not use" brand on the control switch to avoid the danger caused by the wrong startup.
2. When cleaning the wet curtain cold air machine, be careful to remove the wet curtain. When washing, the water pressure should not be too high to prevent the wet curtain from being damaged, and no corrosive chemicals should be put to avoid the corrosion of the wet curtain.
3. It is necessary to fasten the safety belt when working at height to ensure safety.