Dynamic News

——

Is there any difference between industrial air coolers and mobile environmental air conditioners?

From a technical point of view, their cooling and cooling principles are the same. The power and cooling capacity of industrial coolers and mobile environmental air-conditioning are basically the same. The difference is that the air duct of the industrial air cooler is cyclically designed. The air volume circulation of the mobile environmental protection air conditioner is aimed at the indoor air circulation, while the industrial air cooler is to reduce the indoor air temperature while sucking in fresh outdoor air to ensure that In the exchange of air, there will never be an "air conditioning disease". This fresh air duct design does not cause the indoor temperature to drop very low. In the case of an external temperature of 36 ° C, the indoor temperature is about 28 ° C, and the local temperature can reach 25 ° C. When buying, consumers must be aware that the biggest feature of mobile environmental protection air conditioning is that it can cool down in a local area!

Is there any difference between industrial air coolers and mobile environmental air conditioners?

  common problem 
1. Is the use of mobile environmental air conditioning complicated?
     Answer: Mobile environmental protection air conditioner does not need to be installed like a traditional cooler. After you buy it back, you can open the package and plug it in with water to power on. It is easier than using a fan.

2. Is the wind from the mobile environmental protection air conditioner very humid? Will it affect the appliances?
A: The humidity of the air conditioner of the mobile environmental protection air conditioner is related to the ambient temperature and humidity. Generally, the humidity of the air outlet is about 60-70%, and the farther away it is, the lower the humidity. Generally, the indoor humidity is more than 90% on rainy days. Think about whether it has any effect on the appliance.

Is there any difference between industrial air coolers and mobile environmental air conditioners?

3, does the mobile environmental protection air conditioner need a good indoor cooling effect?
     A: Mobile environmental air conditioners do not need to close the doors and windows when they are used. Mobile environmental air conditioners process the outdoor air into cool fresh air and continuously transport it indoors, while driving the sweltering air out of the room. It is a large circulation inside and outside rather than a closed room. Circulation, so it has the role of purifying indoor air.

What to do if the cooling effect of the air cooler is not obvious

The cold air blower uses the evaporation of water to reduce the temperature in the air. The cooler has good ventilation effect and fast cooling speed, so it has a wide range of applications and a large market demand. Improper use of a cooler for a long time will cause its cooling effect to decline. Let's take a look at the main factors that affect the cooling effect of a cooler.
       
    There are many factors that affect the cooling effect of the air cooler. The first point is that the maintenance and cleaning work on weekdays is not done well, and a large amount of dust is blocked in the evaporation port of the filter, which affects the cooling effect of the air cooler. The second point is that the dirt on the bottom plate of the machine is not cleaned in time, which causes the cooling fan to malfunction. The third point is that the quality of the air cooler itself is not enough, the structural design is not reasonable, and the fourth is that the air cooler body does not have its own dirt cleaning function. The last point is that the chiller accessories are not turned off, which causes the voltage to be unstable, which affects the normal working process.
    
    What should we do when the cooling effect of the air cooler is not obvious?
    
    1. Open the doors and windows of the air cooler. This can increase the air flow speed around the air cooler.
    2. Check whether the water level probe is correctly installed and whether the pump stops working.
    3. The staff should regularly clean the dust-susceptible working accessories of the air cooler: water pipes, filters and other parts.
    4. In humid weather, the cooling effect is worse than in dry weather. This is a normal phenomenon and you don't need to worry. The reason for this phenomenon is due to the poor air circulation in humid weather, and the performance of the cooling effect is relatively weak.

Why did the shop choose a cooler to cool down?

The air cooler is a product between the fan and the air conditioner. It is cooler than the ordinary fan, but it is not as cool as the air conditioner, and it can also ensure the freshness of the air. Therefore, more and more manufacturers choose to cool the air cooler. We are specific Let's see what advantages it has. Ningbo air cooler, Ningbo air cooler

1. The air cooler is very environmentally friendly. This is because it is an environmentally friendly product. By virtue of environmentally friendly products without compressors, refrigerants, and pollution, only the outdoor air is used to match the indoor air to achieve what we need. effect.

2. The cost of the air cooler is very low. This is also a point where many people choose the air cooler. We must know that the air cooler is very energy efficient compared to other air conditioners.

3. The cooling effect of the air cooler is very outstanding, whether it is the south or the north; and it is not only refrigeration, but also ensures the freshness of the air.

4. Dust-proof, using the cooling cooler of the factory workshop, which is based on the principle of evaporation and cooling. As the moisture evaporates, it can effectively purify the dust in the air, so the workshop cooling equipment can also play a certain role in removing dust when it is used. .

5. Deodorization. In the case that the air cooler on the factory floor can play a certain ventilation function through its own function, it will certainly be able to remove the odor generated in the workshop due to production and processing.

      6. In terms of installation, the air cooler has its own unique features compared with other air conditioners. It is not only simple to install but also very easy to maintain.

      Use energy-saving and environmentally friendly air cooler to cool down, comfortable and comfortable, no discomfort for long time blowing. From the perspective of long-term economic benefits and costs, it is more economical to choose an energy-saving and environmentally friendly air-cooler workshop to cool down. It not only has low operating costs, but also integrates economic and environmental protection with ventilation and cooling.

How to replace the belt of negative pressure fan?

The belt of the negative pressure fan is a plastic product that is easy to wear and age. It needs to be replaced frequently during long-term use, but I do n’t know how to operate it. I will share a method of replacing the belt of the negative pressure fan for your reference. .

    Step 1: Disconnect the main power supply of the negative pressure fan, remove the wiring on the fan switch, and ensure that the negative pressure fan motor and the machine body are not energized. Do not replace the belt while the power is on.

    The second step is to use a screwdriver to loosen the protective net fixed on the air inlet of the negative pressure fan. Generally, this net is oriented to people standing indoors. Remove the protective net completely and set it aside. Do not hinder belt replacement.

    The third step is to find the screw that fixes the motor on the panel of the negative pressure fan, and loosen the fixing screw with a wrench, so that the motor can slide left and right on the track freely.

    The fourth step is to remove the worn belts in the reverse direction of the fan blade rotation, and slowly remove the belt from the gap between the fan blades by turning the fan blades. Be careful not to scratch your hands while rotating the fan blades.

    Step 5: Take out the new belt and rotate the fan blades into the large pulley from the gap between the fan blades.

    The sixth step is to adjust the fixed position of the motor on the track according to the tightness of the belt, tighten the screws of the fixed track on the motor with a wrench, and put the other end of the belt into the pulley of the motor.

    Step 7. Install the safety net removed in the previous step and use a screwdriver to install it back.

    Step 8. Reconnect the power supply and the circuit on the motor according to the requirements of the negative pressure fan. Use an electric pen or multimeter to test whether the circuit is normal. If normal, you can power on and use it.